<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.zbc.uz.zgora.pl/repozytorium/style/common/xsl/oai-style.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" 
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
         http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-06-28T05:09:35Z</responseDate>
	<request identifier="oai:zbc.uz.zgora.pl:72746" metadataPrefix="oai_dc" verb="GetRecord">
	https://zbc.uz.zgora.pl/repozytorium/oai-pmh-repository.xml</request>
	<GetRecord>
	
  <record>
	<header>
		<identifier>oai:zbc.uz.zgora.pl:72746</identifier>
	    <datestamp>2023-07-06T08:42:31Z</datestamp>
		  <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:CEER:CEER21</setSpec> 	      <setSpec>DigitalLibraryZielonaGora</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties:FacultyCivilArchitectureEnvironmental</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:CEER</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork:Articles</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals</setSpec> 	    </header>
		<metadata>
	<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="pl"><![CDATA[A Method to Reduce Air Heating Costs in Winter Period in The Królowa Luiza Mining Museum in Zabrze - Case Study]]></dc:title>
<dc:creator><![CDATA[Słota, Krzysztof]]></dc:creator>
<dc:creator><![CDATA[Słota, Zbigniew]]></dc:creator>
<dc:subject xml:lang="pl"><![CDATA[Mining Museum in Zabrze]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[tourist traffic]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[air heating]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[reducing costs]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[ventilation]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[recuperation]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[Muzeum Górnictwa w Zabrzu]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[ruch turystyczny]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[ogrzewanie powietrza]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[obniżenie kosztów]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[wentylacja]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[rekuperacja]]></dc:subject>
<dc:description xml:lang="pl"><![CDATA[The Królowa Luiza Mining Museum is one of the touristic objects of the Coal Mining Museum in Zabrze. In the study in concern, an assessment of ventilation of the facility was conducted. Following the assessment of the ventilation, the operating parameters of the fans were changed, inlets were sealed and a system of air ducts was designed and constructed. The ducts reintroduce the heated air from the facility to workings.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[The conducted activities aimed to decrease the amount of air has increased the temperature in the entire object by from 3 to 10 degress C, which translated into a profit of approximately 200 Euro a day. Before changing the heating system it was impossible to achieve a positive temperature in the entire object at an external temperature of -10 degress C. It was necessary to close the Museum for tourists.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[Trials conducted for the external temperature from -2 to -6 degress C have exhibited that it will be possible to achieve positive temperatures in the entire facility even in case of very low external temperatures. The costs borne for the change of the heating system may be estimated at a level of 25000 Euro. The return of the investment should occur in the first Winter period.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[tytuł dodatkowy: Prace z Inżynierii Lądowej i Środowiska]]></dc:description>
<dc:publisher><![CDATA[Zielona Góra: Oficyna Wydawnicza Uniwersytetu Zielonogórskiego]]></dc:publisher>
<dc:contributor><![CDATA[Kuczyński, Tadeusz - red.]]></dc:contributor>
<dc:date><![CDATA[2021]]></dc:date>
<dc:type xml:lang="pl"><![CDATA[artykuł]]></dc:type>
<dc:format xml:lang="pl"><![CDATA[application/pdf]]></dc:format>
<dc:identifier><![CDATA[http://www.zbc.uz.zgora.pl/repozytorium/Content/72746/ceer2021_2_slota_a-method.pdf]]></dc:identifier>
<dc:identifier><![CDATA[https://zbc.uz.zgora.pl/repozytorium/dlibra/publication/79738/edition/72746/content]]></dc:identifier>
<dc:identifier><![CDATA[oai:zbc.uz.zgora.pl:72746]]></dc:identifier>
<dc:source xml:lang="pl"><![CDATA[Civil and Environmental Engineering Reports (CEER), no 31, vol. 2]]></dc:source>
<dc:language><![CDATA[eng]]></dc:language>
<dc:relation><![CDATA[oai:zbc.uz.zgora.pl:publication:79738]]></dc:relation>
<dc:rights xml:lang="pl"><![CDATA[Biblioteka Uniwersytetu Zielonogórskiego]]></dc:rights>
</oai_dc:dc>

</metadata>
	  </record>	</GetRecord>
</OAI-PMH>
