<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.zbc.uz.zgora.pl/repozytorium/style/common/xsl/oai-style.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" 
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
         http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-06-28T05:04:49Z</responseDate>
	<request identifier="oai:zbc.uz.zgora.pl:68125" metadataPrefix="oai_dc" verb="GetRecord">
	https://zbc.uz.zgora.pl/repozytorium/oai-pmh-repository.xml</request>
	<GetRecord>
	
  <record>
	<header>
		<identifier>oai:zbc.uz.zgora.pl:68125</identifier>
	    <datestamp>2023-07-06T08:42:31Z</datestamp>
		  <setSpec>DigitalLibraryZielonaGora</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:CEER:CEER19</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties:FacultyCivilArchitectureEnvironmental</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:CEER</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork:Articles</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals</setSpec> 	    </header>
		<metadata>
	<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="pl"><![CDATA[Investigation on electrically conductive aggregates as grounding compound produced by Marconite]]></dc:title>
<dc:creator><![CDATA[Mohd Tadza, Mohd Yuhyi]]></dc:creator>
<dc:creator><![CDATA[Tengku Anuar, Tengku Hafidatul Husna]]></dc:creator>
<dc:creator><![CDATA[Mat Yahaya, Fadzil]]></dc:creator>
<dc:subject xml:lang="pl"><![CDATA[grounding system]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[conductive aggregate]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[Marconite]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[ground enhancement material]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[resistivity]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[grounding compound]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[system uziemienia]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[kruszywo przewodzące]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[materiał uszlachetniający]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[oporność]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[masa uziemiająca]]></dc:subject>
<dc:description xml:lang="pl"><![CDATA[Marconite is often used as alternative material to improve the performance of earth grounding system. This study aims to investigate of the physical and mechanical behaviour of conductive aggregate derived from Marconite namely, the electrical resistivity, water absorption, and crushing strength. In addition, similar tests were also conducted on mortar aggregate for comparison. The resistivity of aggregates were measured using soil box method.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[Test results showed that Th e electrical resistivity, water absorption, and crushing strength of both aggregates varied with time. These values were found to be stabilised after approximately after 14 days. The electrical resistivity for aggregates containing Marconite were found to be 39.2 [omega].m, far lower than 12700 [omega].m obtained for mortar-based aggregates. Similarly, the water absorption for Marconite aggregates were greater compared to mortar aggregates.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[On the other hand, the crushing strength for Marconite aggregates was to be lower. Incorporating Marconite significantly improved the electrical resistivity behaviour while maintaining acceptable mechanical properties crucial for electrical grounding purposes.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[tytuł dodatkowy: Prace z Inżynierii Lądowej i Środowiska]]></dc:description>
<dc:publisher><![CDATA[Zielona Góra: Oficyna Wydawnicza Uniwersytetu Zielonogórskiego]]></dc:publisher>
<dc:contributor><![CDATA[Kuczyński, Tadeusz - red.]]></dc:contributor>
<dc:date><![CDATA[2019]]></dc:date>
<dc:type xml:lang="pl"><![CDATA[artykuł]]></dc:type>
<dc:format xml:lang="pl"><![CDATA[application/pdf]]></dc:format>
<dc:identifier><![CDATA[http://www.zbc.uz.zgora.pl/repozytorium/Content/68125/ceer2019_3_tengku_investigation.pdf]]></dc:identifier>
<dc:identifier><![CDATA[https://zbc.uz.zgora.pl/repozytorium/dlibra/publication/75048/edition/68125/content]]></dc:identifier>
<dc:identifier><![CDATA[oai:zbc.uz.zgora.pl:68125]]></dc:identifier>
<dc:source xml:lang="pl"><![CDATA[Civil and Environmental Engineering Reports (CEER), no 29, vol. 3]]></dc:source>
<dc:language><![CDATA[eng]]></dc:language>
<dc:relation><![CDATA[oai:zbc.uz.zgora.pl:publication:75048]]></dc:relation>
<dc:rights xml:lang="pl"><![CDATA[Biblioteka Uniwersytetu Zielonogórskiego]]></dc:rights>
</oai_dc:dc>

</metadata>
	  </record>	</GetRecord>
</OAI-PMH>