<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.zbc.uz.zgora.pl/repozytorium/style/common/xsl/oai-style.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" 
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
         http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-06-28T07:07:16Z</responseDate>
	<request identifier="oai:zbc.uz.zgora.pl:47251" metadataPrefix="oai_dc" verb="GetRecord">
	https://zbc.uz.zgora.pl/repozytorium/oai-pmh-repository.xml</request>
	<GetRecord>
	
  <record>
	<header>
		<identifier>oai:zbc.uz.zgora.pl:47251</identifier>
	    <datestamp>2023-07-06T08:42:31Z</datestamp>
		  <setSpec>DigitalLibraryZielonaGora</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:CEER:CEER12</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties:FacultyCivilArchitectureEnvironmental</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:CEER</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork:Articles</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals</setSpec> 	    </header>
		<metadata>
	<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="pl"><![CDATA[Comparison of the calculation results of heat exchange between a single-family building and the ground obtained with the quasi-stationary and 3-d transient models. Part 1: continuous heating mode = Porównanie wyników obliczeń wymiany ciepła jednorodzinnego budynku mieszkalnego z gruntem uzyskanych za pomocą metody quasi-stacjonarnej oraz modelu niestacjonarnego trójwymiarowego. Część I: ogrzewanie ciągłe]]></dc:title>
<dc:creator><![CDATA[Staszczuk, Anna]]></dc:creator>
<dc:subject xml:lang="pl"><![CDATA[wymiana ciepła]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[wymiana ciepła z gruntem]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[ogrzewanie ciągłe]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[obliczenia quasi-stacjonarne]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[budynek jednorodzinny]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[heat transfer via the ground]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[heat exchanger]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[continuous heating]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[quasi-stationary calculations]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[single-family building]]></dc:subject>
<dc:description xml:lang="pl"><![CDATA[The paper provides comparative results of calculations of heat exchange between ground and typical residential buildings using simplified (quasi-stationary) and more accurate (transient, three-dimensional) methods. Such characteristics as building?s geometry, basement hollow and construction of ground touching assemblies were considered including continous heating mode.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[The calculations with simplified methods were conducted in accordance with currently valid norm: PN-EN ISO 13370:2008. Thermal performance of buildings. Heat transfer via the ground. Calculation methods. Comparative estimates concerning transient, 3D, heat flow were performed with computer software WUFI?plus. The differences of heat exchange obtained using more exact and simplified methods have been specified as a result of the analysis.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[tytuł dodatkowy: Prace z Inżynierii Lądowej i Środowiska]]></dc:description>
<dc:publisher><![CDATA[Zielona Góra: Oficyna Wydawnicza Uniwersytetu Zielonogórskiego]]></dc:publisher>
<dc:contributor><![CDATA[Kuczma, Mieczysław - red.]]></dc:contributor>
<dc:date><![CDATA[2012]]></dc:date>
<dc:type xml:lang="pl"><![CDATA[artykuł]]></dc:type>
<dc:format xml:lang="pl"><![CDATA[application/pdf]]></dc:format>
<dc:identifier><![CDATA[http://www.zbc.uz.zgora.pl/repozytorium/Content/47251/8_staszczuk_comparison.pdf]]></dc:identifier>
<dc:identifier><![CDATA[https://zbc.uz.zgora.pl/repozytorium/dlibra/publication/55525/edition/47251/content]]></dc:identifier>
<dc:identifier><![CDATA[oai:zbc.uz.zgora.pl:47251]]></dc:identifier>
<dc:source xml:lang="pl"><![CDATA[Civil and Environmental Engineering Reports (CEER), No 8]]></dc:source>