<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.zbc.uz.zgora.pl/repozytorium/style/common/xsl/oai-style.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" 
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
         http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-06-28T06:29:49Z</responseDate>
	<request identifier="oai:zbc.uz.zgora.pl:47184" metadataPrefix="oai_dc" verb="GetRecord">
	https://zbc.uz.zgora.pl/repozytorium/oai-pmh-repository.xml</request>
	<GetRecord>
	
  <record>
	<header>
		<identifier>oai:zbc.uz.zgora.pl:47184</identifier>
	    <datestamp>2023-07-06T08:42:31Z</datestamp>
		  <setSpec>DigitalLibraryZielonaGora</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:CEER:CEER11</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties:FacultyCivilArchitectureEnvironmental</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:CEER</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork:Articles</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals</setSpec> 	    </header>
		<metadata>
	<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="pl"><![CDATA[Modeling performance in reverse osmosis wastewater treatment post-trial coke in the integrated systems based on the assumptions of the relaxation model = Modelowanie wydajności procesu odwróconej osmozy w oczyszczaniu poprocesowych wód koksowniczych w układzie zintegrowanym w oparciu o założenia modelu relaksacyjnego]]></dc:title>
<dc:creator><![CDATA[Mielczarek, Karolina]]></dc:creator>
<dc:creator><![CDATA[Bohdziewicz, Jolanta]]></dc:creator>
<dc:creator><![CDATA[Kwarciak-Kozłowska, Anna]]></dc:creator>
<dc:subject xml:lang="pl"><![CDATA[oczyszczanie ścieków koksowniczych]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[koagulacja objętościowa]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[model relaksacyjny]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[odwrócona osmoza]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[coking wastewater]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[volume coagulation]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[advanced oxidation]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[relaxation model]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[reverse osmosis]]></dc:subject>
<dc:description xml:lang="pl"><![CDATA[The paper presents the results of studies on coking wastewater, coming from the coke plant "Koksownia Czestochowa Nowa" in two integrated systems associating coagulation volume and advanced oxidation with reverse osmosis. The process of coagulation were performed using iron sulfate (III), (PIX 113) of 400 mg/dm3 and wastewater acidity at pH = 9.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[The second processes - advanced oxidation was carried out using Fenton's reagent. The concentration of iron (II) was 0.8 g/dm3 and hydrogen peroxide 2.4 g/dm3. Coke post-process water after its initial treatment was subjected to high-pressure membrane filtration. In the process of reverse osmosis a flat polyamide membrane ADF of Osmonics was used.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[Transmembrane pressure was 2 MPa and the linear speed of water on the membrane surface of 2m/s. Comparison of the effectiveness of wastewater treatment in both tested systems has shown that the system combining the advanced oxidation with reverse osmosis is more effective. In addition, this study attempts to model effectiness of the process of reverse osmosis in both studied systems, based on the assumptions of a relaxation model.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[An experimentally determined dependence of changes in volume of treated wastewater fluxes from the time of the high-pressure membrane filtration, and the values of time constant efficiency of the process characterized by a decrease to below economic viability allowed us fo verify this model.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[tytuł dodatkowy: Prace z Inżynierii Lądowej i Środowiska]]></dc:description>
<dc:publisher><![CDATA[Zielona Góra: Oficyna Wydawnicza Uniwersytetu Zielonogórskiego]]></dc:publisher>
<dc:contributor><![CDATA[Kuczma, Mieczysław - red.]]></dc:contributor>
<dc:date><![CDATA[2011]]></dc:date>
<dc:type xml:lang="pl"><![CDATA[artykuł]]></dc:type>
<dc:format xml:lang="pl"><![CDATA[application/pdf]]></dc:format>
<dc:identifier><![CDATA[http://www.zbc.uz.zgora.pl/repozytorium/Content/47184/CEER6-02_K.Mielczarek-et.al.pdf]]></dc:identifier>
<dc:identifier><![CDATA[https://zbc.uz.zgora.pl/repozytorium/dlibra/publication/55304/edition/47184/content]]></dc:identifier>
<dc:identifier><![CDATA[oai:zbc.uz.zgora.pl:47184]]></dc:identifier>
<dc:source xml:lang="pl"><![CDATA[Civil and Environmental Engineering Reports (CEER), No 6]]></dc:source>
<dc:language><![CDATA[eng]]></dc:language>
<dc:relation><![CDATA[oai:zbc.uz.zgora.pl:publication:55304]]></dc:relation>
<dc:rights xml:lang="pl"><![CDATA[Biblioteka Uniwersytetu Zielonogórskiego]]></dc:rights>
</oai_dc:dc>