<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.zbc.uz.zgora.pl/repozytorium/style/common/xsl/oai-style.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" 
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
         http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-06-28T09:20:52Z</responseDate>
	<request identifier="oai:zbc.uz.zgora.pl:45223" metadataPrefix="oai_dc" verb="GetRecord">
	https://zbc.uz.zgora.pl/repozytorium/oai-pmh-repository.xml</request>
	<GetRecord>
	
  <record>
	<header>
		<identifier>oai:zbc.uz.zgora.pl:45223</identifier>
	    <datestamp>2023-04-18T11:23:53Z</datestamp>
		  <setSpec>DigitalLibraryZielonaGora</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:InzSrodowiska:IS01</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:Faculties:FacultyCivilArchitectureEnvironmental</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:TypesWork:Articles</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals</setSpec> 	      <setSpec>DigitalLibraryZielonaGora:Repository:ListJurnals:InzSrodowiska</setSpec> 	    </header>
		<metadata>
	<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en"><![CDATA[Przydatność kondycjonowania popłuczyn wapnem w aspekcie odprowadzania wód nadosadowych do wód powierzchniowych = Advantages of lime-aided conditioning of filter backwash water in terms of discharging supernatant to ground water]]></dc:title>
<dc:title xml:lang="pl"><![CDATA[Przydatność kondycjonowania popłuczyn wapnem w aspekcie odprowadzania wód nadosadowych do wód powierzchniowych = Advantages of lime-aided conditioning of filter backwash water in terms of discharging supernatant to ground water]]></dc:title>
<dc:creator><![CDATA[Jagoszewski, Tomasz]]></dc:creator>
<dc:creator><![CDATA[Świderska-Bróż, Maria]]></dc:creator>
<dc:subject xml:lang="en"><![CDATA[2 Międzynarodowa konferencja "Ochrona i rekultywacja terenów dorzecza Odry: zagospodarowanie zlewni" (21-22.06.2001)]]></dc:subject>
<dc:subject xml:lang="pl"><![CDATA[2 Międzynarodowa konferencja "Ochrona i rekultywacja terenów dorzecza Odry: zagospodarowanie zlewni" (21-22.06.2001)]]></dc:subject>
<dc:description xml:lang="en"><![CDATA[The paper investigates lime-aided conditioning of filter backwash water from groundwater, infiltrated and surface water treatment plants and its influence on the quality of the supernatant. A thorough analysis of contaminatian levels in the supernatant from non-conditioned and lime-conditioned backwash water has been presented.]]></dc:description>
<dc:description xml:lang="en"><![CDATA[It has been established that manganese and iron concentrations in the supernatant decreased with the increase of pH value of the backwash water. In the case of backwash water from groundwater treatment the same applied to levels of turbidity and suspended solids concentration.]]></dc:description>
<dc:description xml:lang="en"><![CDATA[Lime-aided conditioning of backwash waters containing aluminium compounds caused dissolution of Al(OH)3 to Al(OH)4 and increased aluminium and suspended solids concentratian as well as turbidity of the supernatant and, as a result, proved disadvantageous. Thus, regarding the protection of surface waters, lime conditioning should only be employed to intensify the process of thickening of backwash water from groundwater treatment when the permissible pH value of the supernatant discharged to surface waters is not exceeded.]]></dc:description>
<dc:description xml:lang="en"><![CDATA[nr 5-11 tytuł: Politechnika Zielonogórska - Zeszyty Naukowe]]></dc:description>
<dc:description xml:lang="en"><![CDATA[nr 1-4 tytuł: Wyższa Szkoła Inżynierska im. Jurija Gagarina w Zielonej Górze - Zeszyty Naukowe]]></dc:description>
<dc:description xml:lang="en"><![CDATA[seria główna: Zeszyty Naukowe]]></dc:description>
<dc:description xml:lang="en"><![CDATA[zeszyt 11 ukazał się jako nr 125 serii głównej]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[The paper investigates lime-aided conditioning of filter backwash water from groundwater, infiltrated and surface water treatment plants and its influence on the quality of the supernatant. A thorough analysis of contaminatian levels in the supernatant from non-conditioned and lime-conditioned backwash water has been presented.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[It has been established that manganese and iron concentrations in the supernatant decreased with the increase of pH value of the backwash water. In the case of backwash water from groundwater treatment the same applied to levels of turbidity and suspended solids concentration.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[Lime-aided conditioning of backwash waters containing aluminium compounds caused dissolution of Al(OH)3 to Al(OH)4 and increased aluminium and suspended solids concentratian as well as turbidity of the supernatant and, as a result, proved disadvantageous. Thus, regarding the protection of surface waters, lime conditioning should only be employed to intensify the process of thickening of backwash water from groundwater treatment when the permissible pH value of the supernatant discharged to surface waters is not exceeded.]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[nr 5-11 tytuł: Politechnika Zielonogórska - Zeszyty Naukowe]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[nr 1-4 tytuł: Wyższa Szkoła Inżynierska im. Jurija Gagarina w Zielonej Górze - Zeszyty Naukowe]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[seria główna: Zeszyty Naukowe]]></dc:description>
<dc:description xml:lang="pl"><![CDATA[zeszyt 11 ukazał się jako nr 125 serii głównej]]></dc:description>
<dc:publisher><![CDATA[Zielona Góra: Oficyna Wydawnicza Uniwersytetu Zielonogórskiego]]></dc:publisher>
<dc:date><![CDATA[2001]]></dc:date>
<dc:type xml:lang="en"><![CDATA[artykuł]]></dc:type>
<dc:type xml:lang="pl"><![CDATA[artykuł]]></dc:type>
<dc:format xml:lang="en"><![CDATA[application/pdf]]></dc:format>
<dc:format xml:lang="pl"><![CDATA[application/pdf]]></dc:format>
<dc:identifier><![CDATA[http://www.zbc.uz.zgora.pl/repozytorium/Content/45223/PDF/16_jagoszewski_przydatnosc.pdf]]></dc:identifier>
<dc:identifier><![CDATA[https://zbc.uz.zgora.pl/repozytorium/dlibra/publication/51451/edition/45223/content]]></dc:identifier>
<dc:identifier><![CDATA[oai:zbc.uz.zgora.pl:45223]]></dc:identifier>
<dc:source xml:lang="en"><![CDATA[Politechnika Zielonogórska Wydział Budownictwa i Inżynierii Sanitarnej - Zeszyty Naukowe: Inżynieria Środowiska, nr 11]]></dc:source>
<dc:source xml:lang="pl"><![CDATA[Politechnika Zielonogórska Wydział Budownictwa i Inżynierii Sanitarnej - Zeszyty Naukowe: Inżynieria Środowiska, nr 11]]></dc:source>
<dc:language><![CDATA[eng]]></dc:language>
<dc:language><![CDATA[pol]]></dc:language>
<dc:relation><![CDATA[oai:zbc.uz.zgora.pl:publication:51451]]></dc:relation>
<dc:rights xml:lang="en"><![CDATA[Biblioteka Uniwersytetu Zielonogórskiego]]></dc:rights>
<dc:rights xml:lang="pl"><![CDATA[Biblioteka Uniwersytetu Zielonogórskiego]]></dc:rights>
</oai_dc:dc>

</metadata>
	  </record>	</GetRecord>
</OAI-PMH>