@misc{Myszograj_Sylwia_Efektywność, author={Myszograj, Sylwia and Panek, Ewa and Wołoszyn, Jerzy}, howpublished={online}, publisher={Zielona Góra: Oficyna Wydawnicza Uniwersytetu Zielonogórskiego}, language={pol}, language={eng}, abstract={This paper presents the technology of solar drying of sewage sludge in wastewater treatment plant in Żary. Analysis of 18 months operation of the system showed that the effect of drying was achieved by 5-fold decrease by weight of sludge. The average moisture of the sludge was 12.3% at the start stage in 2009.}, abstract={Average moisture of the dried sludge in 2010 was 34.1%, and taking into account the months in which the drying takes deposits, but not dry - 50.5%. Electricity consumption in 2010 by all the drying halls was 20 628 kWh, which gives 32.4 kWh/tonne of dried and 13.83 kWh/tonne of evaporated water.}, abstract={Summary consumption of electricity by drying halls in 2010 was 1.03% of total energy consumption and was approximately equivalent to the amount of energy consumed by the plant within three days of operation.}, type={artykuł}, title={Efektywność solarnej suszarni osadów ściekowych w Żarach = Efficiency of solar sludge dryers in Żary}, keywords={osady ściekowe, suszarnia solarna, efektywność, sewage sludge, solar drying, efficiency}, }